HIGH EFFICIENCY ROOF-MOUNT POWER VENT

 

Variable speed motor ramps up as needed, maximizing energy efficiency.

High Efficiency Power Vent

 

 

Description

Going Green Saves GreenElectric-powered attic vents use a thermostat to fight heat and a humidistat control to help prevent moisture buildup inside the attic.

 

The 1500 CFM High Efficiency Power Fan utilizes an electronically commutated motor (ECM). This “smart motor” is equipped with an on-board computer that has temperature and humidity sensors built in. The fan starts on low and only runs at full speed when needed which saves the homeowner up to 74% in energy savings.

 

Power savings - variable speed motor runs at reduced speed under moderate attic temperature/humidity conditions. Motor ramps up in speed only as needed maximizing energy efficiency.

Soft start motor - starts up slowly and only ramps up as needed. This provides a quiet start up and reduces wear and tear on the motor.

Prolonged life - slow start, turns off when too hot or when raining, and only runs on high when needed.

  

  Energy and Cost Savings:

 HE15 Energy and Cost Savings

 

HE15 Specifications

 

HE15 Product Video

 

RELATED DOCUMENTS

 

 

Specifications

SPECIFICATIONS

HOW TO SIZE POWER VENTS?
Power vents are rated in CFM—cubic feet of air moved per minute. The higher the CFM, the more powerful the vent and the more air exchanges per hour it provides. To determine the minimum CFM required, multiply the attic square footage by 0.7. For example:


1500 square feet x 0.7 = 1050 CFM
Thus, a fan rated at least 1050 CFM is needed


HOW MUCH INTAKE VENTILATION?
Just like any exhaust vent power vents need intake airflow to perform properly. To calculate how much intake the power vent needs simply divide the fan's CFM capacity by 300 and then convert that number to square inches.

  CFM of Power Vent

300
= Square feet of
intake net free area needed
x 144 = Square inches of
intake net free area needed
  For example:    
  1050 CFM

300
= 3.5 Square feet of
intake net free area needed
x 144 = 504 Square inches of
intake net free area needed

AIR VENT POWER VENTS

 

  Color Model Part No. Pcs/Ctn Ctns/Pallet
Power Cool Plus Power Attic Ventilators          
Roof-Mount Metal with pre-wired Humidistat/Thermostat
1500 CFM
Gray ASRHPGR 53850 1 30
  Weatherwood ASRHPWW 53849 1 30
  Brown ASRHPBR 53848 1 30
  Black ASRHPBK 53847 1 30
           
           
Roof-Mount Metal with pre-wired Thermostat 1500 CFM Brown SV3000BR 53853 1 30
  Weatherwood SV3000WW 53854 1 30
           
           
           
Roof-Mount Metal with pre-wired Humidistat/Thermostat
1170 CFM
Gray  PC12GR  97711  1 30 
  Weatherwood  PC12WW  97712  1 30 
  Brown  PC12BR  97713  1 30 
  Black  PC12BK  97714  1 30 
           
Roof-Mount Metal with Thermostat 1320 CFM Gray RV28ML 53833 1 30
  Weatherwood RV28WW 53832 1 30
           
Roof-Mount Metal with Thermostat 1170 CFM Gray RV26GR 53830 1 30
  Brown RV26BR 53827 1 30
  Black RV26BK 53871 1 30
  Weatherwood RV26WW 53829 1 30
           
Roof-Mount Plastic with Thermostat 1170 CFM Gray RV26GR 53828 1 30
           
 Gable-Mount Power Attic Ventilators          
Gable-Mount with Humidistat/Thermostat 1620 CFM   APGH  53320  1 64
Gable-Mount with Thermostat 1620 CFM   APG 53316 1 64
Gable-Mount with Thermostat only 1320 CFM   WCGB  53319  1 64
Gable-Mount with Thermostat 1050 CFM   WCGA 53315 1 64
Solar Power Gable-Mounts    NPSG8  53560  1 60
Automatic Gable Shutter (white only)   SHT15W  54703  1 160 
           
Solar Powered Attic Ventilators          
30-Watt Solar Roof-Mount Black 9930TRS 97326 1 18
20-Watt Solar Roof-Mount with Solar Controller Humidistat/Thermostat Black 9920TR 97330 1 18
12-Watt Solar Roof-Mount Black 9912TR 97329 1 18
SolarCool Roof-Mount Metal Black SC8BL 97310 1 18
           
High Efficiency          
High Efficiency Roof-Mount Power Vent Weatherwood HE15WW 53900 1 30

 

 

 

Installation Instructions

 

Installation Instructions

 

 

 

Warranty

WARRANTY

Learn about warranty coverage, transferability, limitations, other conditions and customer responsibilities.

 

Read the full warranty and the list of eligible products.

 

For Warranty information and questions, please contact us at: warranty@gibraltar1.com 

 

Warranty Download Download Full Air Vent Warranty Information

 

Limited Warranty
The Air Vent Product that you have purchased has a limited warranty from the date of purchase against defects in workmanship and materials. The length of the warranty varies by product. Please see attached chart for details. This warranty does not cover any labor costs, including those required for field repair or replacement or removal of any allegedly defective part.

 

Proof of purchase is required when requesting warranty service.
The original purchaser must present a sales receipt or other document that establishes proof of purchase.
Please do not ship your fan or any fan parts to Air Vent unless requested to do so.

 

Limitations
Air Vent shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with misuse, abuse, neglect or improper handling or staging , or installation not in strict adherence to Air Vent’s written instructions; impact of foreign objects, fire, flood, earthquake, lightning, hurricane, hail, tornado or other violent storms or other act of God; or defects in failure of or damage caused by materials used as roofing base over which the product is installed or by movement, distortion, cracking or settling of walls or the foundation of the building.

Air Vent reserves the right to discontinue or modify any of its products including color, and shall not be liable as a result of such discontinuation or modification, nor shall Air Vent be liable in the event replacement material may vary in color in comparison to the original product as a result of normal weathering. If Air Vent replaces any product under this warranty, it may substitute products designated by Air Vent to be of comparable quality or price range in the event the product initially installed has been discontinued or modified.

 

Replacement Plus™ Protection
Products are covered by Replacement Plus™ protection (see attached for applicable products) for a period of time (varies by product) provided that the product has been installed in strict accordance with Air Vent’s written installation instructions. Under this warranty feature, Air Vent, at no charge, will replace any product found to be defective during the Replacement Plus™ period as long as proof of purchase is submitted to Air Vent (Replacement Plus™ period begins when the product installation is completed). Air Vent’s maximum liability under Replacement Plus will be equal to the reasonable cost to replace the defective product, including labor.

In instances in which Air Vent, according to the terms of this warranty, has agreed to pay the cost of labor required to replace a defective intake vent, Air Vent will provide reimbursement only upon receipt of a copy of the contractor’s invoice or other written evidence of the completion of the work which Air Vent, at its sole discretion, deems acceptable.

 

Transferability
Provided that the products covered by this warranty have been installed in strict accordance with the Air Vent Inc. written installation instructions and in accordance with all local codes and standards, including those pertaining to fire-rated construction, Air Vent warrants to the original purchaser or first subsequent owner of the property that the product is free from manufacturing defects for the described length below from the date of purchase. If there is a change in ownership, the warranty may be transferred by the original purchaser of the product to the new owner (first subsequent owner) under the terms and conditions of this warranty.

 

Motor Replacements
The electrical motor is to be used solely as a direct replacement for a motor of the same model in an Air Vent, Inc, power attic ventilator. Using the motor in any other product could result in electrical shock and/or fire, which may cause property damage, serious injury or even death. Any motor replacement should be installed by a qualified licensed electrician in accordance with local, state and national electrical codes and standards. Make sure that power to the unit has been completely turned OFF at the breaker before approaching or inspecting the power attic ventilator or installing the replacement motor.

 

Other Conditions
This warranty is expressly in lieu of all other oral or written warranties, liabilities or obligations of Air Vent. Pertinent state law shall control for what period of time subsequent to sale a consumer/homeowner may seek a remedy pursuant to the implied warranty of merchantability or fitness for a particular purpose. In no event shall Air Vent be liable for consequential or incidental damages of any kind, including any damage to the building, its contents or any persons therein, resulting from the breach of any warranty set forth herein, unless exclusion of these types of damages are specifically prohibited by state law. No field representative of Air Vent or any distributor or dealer is authorized to make any change or modifications to this warranty. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

 

The following warranty is effective 3/26/2021.


 Product Model Number  Warranty  Replacement Plus Protection
 ShingleVent ®II ridge vent (12", 9", Class A 9")   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Peak Performer™ I & II Rolled ridge vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 The Edge™ Vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Hip Ridge® Vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 VenturiVent™ Plus ridge vent and rolled ridge vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

ATTIC-AIRE™ ALL SEASONS™ Filtered Ridge Vent and Roll Vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

RidgeHawk™ Rolled ridge vent with nails RH20 Limited Lifetime Warranty  

ShadowHawk® Low Profile Vent LPG72 Limited Lifetime Warranty 5 year Replacement Plus™ protection

Roof Mount Power Vent ASRHP, SV3000, HE15WW Limited Lifetime Warranty 5 year Replacement Plus™ protection

Roof Mount Power Vent RV26, RV28, PC12 10 Year Limited Warranty 5 year Replacement Plus™ protection

Gable-Mount Power Vent APG, APGH Limited Lifetime Warranty 5 year Replacement Plus™ protection

Gable-Mount Power Fans (WCGB)- with Thermostat   Limited Lifetime Warranty 5 year Replacement Plus™ protection

Gable-Mount Power Fans (model WCGA)   5 Year Limited Warranty 5 year Replacement Plus™ protection

Roof Mount Solar Power Fans NPSP8WW, SC8BL 5 Year Limited Warranty 2 year Replacement Plus™ protection

Gable Mount Solar Power Fans NPSG8 5 Year Limited Warranty 2 year Replacement Plus™ protection

 Whole-House Fans   10 Year Limited Warranty 5 year Replacement Plus™ protection

Roof Louvers/Static Vents   5 Year Limited Warranty  

Airhawk® Wind Turbines TIB, TOB series    

Type B Gas Vent Cap PTOP Series 5 Year Limited Warranty  

Automatic Foundation Vent   5 Year Limited Warranty  

Powered Foundation Vent   5 Year Limited Warranty  

Low Voltage Foundation Vent Series 5 & 6, Radon 5 Year Limited Warranty  

Roof Mount Solar Power Fans 9010TR, 9025TR 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

Gable Mount 20 Watt Solar Fan 1125APV 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

Skylight Tubes 2214ST-LK 10 Year Limited Warranty  

Archived Products
 Product Model Number  Warranty  Replacement Plus Protection
ShingleVent ®II ridge vent 7", Class A 7"   Limited Lifetime Warranty 5 year Replacement Plus™ protection

Ridge Vent 20’ MRV20 Limited Lifetime Warranty  

Attic Aire™ Wind Turbines (WT series)   5 Year Limited Warranty  

Roof Mount Solar Power Fans 9910TR, 9920TR, 9930TR 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

Gable Mount 20 Watt Solar Fan 1020APV 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

U.S. Sunlight Solar Controller SC20 1 Year Limited Warranty on Unit, Remote  

Skylight Tubes 1914ST, 2114ST 10 Year Limited Warranty  

 

Success Stories

SUCCESS STORIES

 

Success Story - ShadowHawk Box Vents for Intake (and HE15 Roof-Mount Power Fan for Exhaust)

 

Arrington Roofing Company, Inc.
Address: 2203 Obenchain Street
Dallas, TX 75208
Phone: 214-698-8443
Website: www.arringtonroofing.com

 

“This was a very complicated townhouse reroofing project. There were no eaves for traditional intake ventilation. There were multiple attics. The sloped roof was replaced with synthetic slate. The flat roof areas were reroofed with TPO. Townhouses adjoin on both sides. We used ShadowHawk roof-top box vents for intake and HE15 roof-mount power fans for exhaust. ” – Chris Arrington, vice president, Arrington Roofing Company, Inc.

 

Editor’s Note: ShadowHawk box vents have a streamlined design to allow them to safely shed water in a rain event when placed low on the roof. They are uniquely engineered to work as either intake (positioned low on the roof) or exhaust (positioned high on the roof). The High Efficiency 15 (HE15) roof-mount power fan has a variable speed motor with an on-board computer chip that monitors the conditions of the attic and adjusts the motor’s output accordingly. It can save homeowners on average up to $60 annually on their electricity bill compared to standard power fans. 

 

Click an image to enlarge:

 

Image 1)Complicated roof
Image 2) ShadowHawk close up for intake
Image 3) ShadowHawk for intake; HE15 for exhaust
Image 4) After


 

 

Success Story - ShadowHawk Box Vents for Intake (and HE15 Roof-Mount Power Fan for Exhaust)

 

Arrington Roofing Company, Inc.
Address: 2203 Obenchain Street
Dallas, TX 75208
Phone: 214-698-8443
Website: www.arringtonroofing.com

 

“We used ShadowHawk box vents for intake low on the roof and an HE15 roof-mount power vent for exhaust on this re-roof project. The soffits were exposed rafters covered with vinyl siding. In effect, there was no intake ventilation. The ridge vent you see in one picture is a separate attic. We removed two turbines, two power vents and some ridge vent. ” – Chris Arrington, vice president, Arrington Roofing Company, Inc.

 

Editor’s Note: ShadowHawk box vents are designed to work as either intake (positioned low on the roof) or exhaust (positioned high on the roof). The HE15 roof-mount power fan has a variable speed motor with an on-board computer chip that monitors the conditions of the attic and adjusts the motor’s output accordingly. 

 

Click an image to enlarge:

 

Image 1) ShadowHawk box vents installed
Image 2) HE15 Power Fan installed
Image 3) Moisture buildup can cause roof deck damage


 

 

 

Air Vent Contractor LocatorOur exclusive Contractor Locator will allow you to find contractors in your area who can assist with Air Vent product installation—including solar attic fans and skylight tubes. Click the link below to register and get started.

 

Search for Contractors
Save
Cookies user preferences
We use cookies to ensure you to get the best experience on our website. If you decline the use of cookies, this website may not function as expected.
Accept all
Decline all
Functional
By using this website, you agree to our use of cookies. We use cookies to provide you with a great experience and to help our website run effectively.
Analytics
Tools used to analyze the data to measure the effectiveness of a website and to understand how it works.
Google Analytics
Accept
Decline