Powered Foundation Vents

 

Foundation vents help remove moisture that can lead to damp rot and eventually costly damage, as well as attract termites.

 

Foundation Vents

Description

Foundation vents help remove moisture that can lead to damp rot and eventually costly damage, as well as attract termites.

Powered foundation vents are extremely effective in providing ventilation for moisture control.

A small fan is encased in the housing of the vent and runs continuously at a low speed when the humidity level exceeds the setting on the humidistat. The fan creates negative pressure in the foundation to pull air through the foundation. Powered vents are installed on one side of the foundation, with open, non-powered vents on the other side.

 

Low Voltage Powered Foundation Vents and Radon Powered Foundation Vents

  • 8″ x 16″ to fit into a standard block opening
  • Completely screened, front and back
  • No mortar required for installation
  • Totally enclosed, thermally protected motor
  • Low voltage unit - no electrician required

*Series 5 & 6 Requires controls kit – sold separately

 

Controls Kit 

 Controls Kit

  • Damp Weather Shutoff – dual control adjusts temperature & humidity at intake vent
  • Humidistat – turns unit on to mitigate humidity
  • Power Supply Unit – 24 VAC output, operates up to 3 power vents
  • Control Cables – 25' attaches all control kit units together


KIT REQUIRED ON ALL SERIES 5 AND 6 LOW VOLTAGE
FOUNDATION VENTS (needs accessible GFCI outlet)

 

RELATED DOCUMENTS

 

Specifications

 

Color Model Part No. CFH Pcs/Ctn
Series 6, High Output Black TV6LVHPBL 94004 3000 rpm
1.0 amps, 24 volts
11,160 cubic ft./hr.
 1
Series 5, High Output
removable front frame
Black TV5LVHPBL 94002 3000 rpm
1.0 amps, 24 volts
11,160 cubic ft./hr.
 1
 
Controls Kit
Kit required on all Series 5 and 6
low voltage foundation vents (sold separately)
  LVKIT 94001   1
           
 Accessories  Color  Model     Pcs/Ctn 
Vent Well Black VWBL     1

 Powered Foundation Vent Colors

 

 

 

Warranty

WARRANTY

Learn about warranty coverage, transferability, limitations, other conditions and customer responsibilities.

 

Read the full warranty and the list of eligible products.

 

For Warranty information and questions, please contact us at: warranty@gibraltar1.com 

 

Warranty Download Download Full Air Vent Warranty Information

 

Limited Warranty
The Air Vent Product that you have purchased has a limited warranty from the date of purchase against defects in workmanship and materials. The length of the warranty varies by product. Please see attached chart for details. This warranty does not cover any labor costs, including those required for field repair or replacement or removal of any allegedly defective part.

 

Proof of purchase is required when requesting warranty service.
The original purchaser must present a sales receipt or other document that establishes proof of purchase.
Please do not ship your fan or any fan parts to Air Vent unless requested to do so.

 

Limitations
Air Vent shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with misuse, abuse, neglect or improper handling or staging , or installation not in strict adherence to Air Vent’s written instructions; impact of foreign objects, fire, flood, earthquake, lightning, hurricane, hail, tornado or other violent storms or other act of God; or defects in failure of or damage caused by materials used as roofing base over which the product is installed or by movement, distortion, cracking or settling of walls or the foundation of the building.

Air Vent reserves the right to discontinue or modify any of its products including color, and shall not be liable as a result of such discontinuation or modification, nor shall Air Vent be liable in the event replacement material may vary in color in comparison to the original product as a result of normal weathering. If Air Vent replaces any product under this warranty, it may substitute products designated by Air Vent to be of comparable quality or price range in the event the product initially installed has been discontinued or modified.

 

Replacement Plus™ Protection
Products are covered by Replacement Plus™ protection (see attached for applicable products) for a period of time (varies by product) provided that the product has been installed in strict accordance with Air Vent’s written installation instructions. Under this warranty feature, Air Vent, at no charge, will replace any product found to be defective during the Replacement Plus™ period as long as proof of purchase is submitted to Air Vent (Replacement Plus™ period begins when the product installation is completed). Air Vent’s maximum liability under Replacement Plus will be equal to the reasonable cost to replace the defective product, including labor.

In instances in which Air Vent, according to the terms of this warranty, has agreed to pay the cost of labor required to replace a defective intake vent, Air Vent will provide reimbursement only upon receipt of a copy of the contractor’s invoice or other written evidence of the completion of the work which Air Vent, at its sole discretion, deems acceptable.

 

Transferability
Provided that the products covered by this warranty have been installed in strict accordance with the Air Vent Inc. written installation instructions and in accordance with all local codes and standards, including those pertaining to fire-rated construction, Air Vent warrants to the original purchaser or first subsequent owner of the property that the product is free from manufacturing defects for the described length below from the date of purchase. If there is a change in ownership, the warranty may be transferred by the original purchaser of the product to the new owner (first subsequent owner) under the terms and conditions of this warranty.

 

Motor Replacements
The electrical motor is to be used solely as a direct replacement for a motor of the same model in an Air Vent, Inc, power attic ventilator. Using the motor in any other product could result in electrical shock and/or fire, which may cause property damage, serious injury or even death. Any motor replacement should be installed by a qualified licensed electrician in accordance with local, state and national electrical codes and standards. Make sure that power to the unit has been completely turned OFF at the breaker before approaching or inspecting the power attic ventilator or installing the replacement motor.

 

Other Conditions
This warranty is expressly in lieu of all other oral or written warranties, liabilities or obligations of Air Vent. Pertinent state law shall control for what period of time subsequent to sale a consumer/homeowner may seek a remedy pursuant to the implied warranty of merchantability or fitness for a particular purpose. In no event shall Air Vent be liable for consequential or incidental damages of any kind, including any damage to the building, its contents or any persons therein, resulting from the breach of any warranty set forth herein, unless exclusion of these types of damages are specifically prohibited by state law. No field representative of Air Vent or any distributor or dealer is authorized to make any change or modifications to this warranty. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

 

The following warranty is effective 3/26/2021.


 Product Model Number  Warranty  Replacement Plus Protection
 ShingleVent ®II ridge vent (12", 9", Class A 9")   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Peak Performer™ I & II Rolled ridge vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 The Edge™ Vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Hip Ridge® Vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

 VenturiVent™ Plus ridge vent and rolled ridge vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

ATTIC-AIRE™ ALL SEASONS™ Filtered Ridge Vent and Roll Vent   Limited Lifetime Warranty 5 year Replacement Plus™ protection

RidgeHawk™ Rolled ridge vent with nails RH20 Limited Lifetime Warranty  

ShadowHawk® Low Profile Vent LPG72 Limited Lifetime Warranty 5 year Replacement Plus™ protection

Roof Mount Power Vent ASRHP, SV3000, HE15WW Limited Lifetime Warranty 5 year Replacement Plus™ protection

Roof Mount Power Vent RV26, RV28, PC12 10 Year Limited Warranty 5 year Replacement Plus™ protection

Gable-Mount Power Vent APG, APGH Limited Lifetime Warranty 5 year Replacement Plus™ protection

Gable-Mount Power Fans (WCGB)- with Thermostat   Limited Lifetime Warranty 5 year Replacement Plus™ protection

Gable-Mount Power Fans (model WCGA)   5 Year Limited Warranty 5 year Replacement Plus™ protection

Roof Mount Solar Power Fans NPSP8WW, SC8BL 5 Year Limited Warranty 2 year Replacement Plus™ protection

Gable Mount Solar Power Fans NPSG8 5 Year Limited Warranty 2 year Replacement Plus™ protection

 Whole-House Fans   10 Year Limited Warranty 5 year Replacement Plus™ protection

Roof Louvers/Static Vents   5 Year Limited Warranty  

Airhawk® Wind Turbines TIB, TOB series    

Type B Gas Vent Cap PTOP Series 5 Year Limited Warranty  

Automatic Foundation Vent   5 Year Limited Warranty  

Powered Foundation Vent   5 Year Limited Warranty  

Low Voltage Foundation Vent Series 5 & 6, Radon 5 Year Limited Warranty  

Roof Mount Solar Power Fans 9010TR, 9025TR 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

Gable Mount 20 Watt Solar Fan 1125APV 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

Skylight Tubes 2214ST-LK 10 Year Limited Warranty  

Archived Products
 Product Model Number  Warranty  Replacement Plus Protection
ShingleVent ®II ridge vent 7", Class A 7"   Limited Lifetime Warranty 5 year Replacement Plus™ protection

Ridge Vent 20’ MRV20 Limited Lifetime Warranty  

Attic Aire™ Wind Turbines (WT series)   5 Year Limited Warranty  

Roof Mount Solar Power Fans 9910TR, 9920TR, 9930TR 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

Gable Mount 20 Watt Solar Fan 1020APV 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

U.S. Sunlight Solar Controller SC20 1 Year Limited Warranty on Unit, Remote  

Skylight Tubes 1914ST, 2114ST 10 Year Limited Warranty  

 

Accessories

Humidistats and Thermostats -- A humidistat and thermostat can be installed with the vent to run the fan intermittently. The humidistat turns the fan on when moisture in the foundation rises to a pre-set level. A thermostat should also be connected to the fan to turn the fan off in freezing weather to protect pipes under the home and to save energy.

Call customer service at 1-800-AIR-VENT for more information.

 

Product Photos

PRODUCT PHOTOS

Click an image to enlarge:

 

 

 

 

Product Categories
Exhaust Vents Solar Attic Fans Intake Vents Foundation Vents Whole House Fans Bath or Dryer Vents Skylight Tubes
 
Air Vent Contractor LocatorOur exclusive Contractor Locator will allow you to find contractors in your area who can assist with Air Vent product installation—including solar attic fans and skylight tubes. Click the link below to register and get started.

 

Search for Contractors
Save
Cookies user preferences
We use cookies to ensure you to get the best experience on our website. If you decline the use of cookies, this website may not function as expected.
Accept all
Decline all
Functional
By using this website, you agree to our use of cookies. We use cookies to provide you with a great experience and to help our website run effectively.
Analytics
Tools used to analyze the data to measure the effectiveness of a website and to understand how it works.
Google Analytics
Accept
Decline