Description
There are two great things about Air Vent's 9-inch ShingleVent II Class A shingle-over ridge vents:
- They're fire rated for Class A roof decks.
- They still have the advanced design of other Air Vent ridge vents including the external baffle and internal weather filter for superior airflow performance and weather rotection.
This product proves that outstanding beauty and performance can be combined. Design features include an external baffle and internal weather filter for optimum airflow and weather protection. Less than an inch in height, this molded, high-impact copolymer shingle-over ridge vent permits capping of the ridge with shingles like the rest of the roof.
- For enhanced ridge cap shingles, cedar shake, cedar shingle and tile applications.
- 16 square inches of net free area per linear foot.
- Built-in external baffle deflects wind up and over the ridge enhancing airflow performance.
- Internal weather filter provides protection against weather and insect infiltration.
- Less than 7/8 inches tall on the ridge making them virtually invisible from the ground.
RELATED DOCUMENTS
Features
Product Features
- Class A fire rated. Rated for Class A roof decks in accordance with UL standards for ICC approval. They are the only externally baffled Class A fire-rated shingle-over ridge vents available.
- Exceptional airflow. Built-in external baffle deflects wind up and over the redge, enhancing airflow performance. ShingleVent II Class A provides 16 square inches of net free area per linear foot.
- Advanced weather protection. The external baffle deflects wind and weather over the vent to help protect the attic from rain and snow infiltration.
- Internal weather filter. Provides a more complete barrier to help protect the attic from wind-driven rain, snow, dust and insects.
- Easy Installation. The vent is pre-formed to a 4/12 pitch, and fits pitches from 3/12 to 12/12.
- Virtually invisible. Less than 7/8 inches tall on the ridge makes them virtually invisible from the ground.
- Limited Lifetime Warranty and 5-year Replacement Plus™ Protection.
Specifications
SPECIFICATIONS
When installed properly, all Air Vent products mentioned here comply with the net free area requirements of nationally recognized model codes, including those written by the International Code Council. In addition, the vents have product evaluation approvals from Dade County, Florida, ICC and TDI.
Please call 1-800-AIR-VENT to obtain code body information for a particular Air Vent product.
Here's an overview of the specifications for Air Vent's complete line of ridge ventilation products.
View the wide range of colors in which our products are available in our pdf color chart (12 KB).
Air Vent Color Chart
Download a PDF version of our color chart
THE SIMPLE MATHEMATICS OF A BALANCED RIDGE VENTILATION SYSTEM
- According to most building codes, you need 1 square foot of ventilation for every 150 square feet of attic floor space.
- For new home construction that includes a vapor retarder, the minimum is 1 square foot of ventilation for every 300 square feet of attic floor space.
- If your vents are split between ridge vents and intake vents, the minimum requirement is also 1 square foot of ventilation for every 300 square feet of attic floor space.
To determine how many feet of net free area you need, use this formula:
Square feet of attic floor space 300 |
= | Square feet of net free area needed |
For example: | ||
1500 square feet of attic floor space 300 |
= | 5 square feet of free are a needed |
- To determine how many feet of ShingleVent® II, Multi-Pitch FilterVent® or VenturiVent Plus™ you need, use this formula:
- 1/2 net free area x 144 ÷ 18 = feet of ridge vent needed
- For example: 2.5 (based on net free area of 5 square feet) x 144 ÷ 18 = 20 feet of ridge vent needed
- To determine how many feet of Air Vent soffit vents you need, use this formula:
- 1/2 net free area x 144 ÷ 9 = feet of soffit vent needed
- For example: 2.5 (based on net free area of 5 square feet) x 144 ÷ 9 = 40 feet of soffit vent needed
- The following charts may be used to:
- 1. Determine how much net free area is needed to satisfy FHA requirements.
- 2. Balance your ridge vent system.
DETERMINING VENTILATION REQUIREMENTS
Attic Square Footage |
Min. Net Free Area Required (if balanced between intake and exhaust) |
Min Length of Ridge |
|
1200 1500 1800 2100 2400 2600 3000 3300 |
4' 5' 6' 7' 8' 9' 10' 11' |
576" 720" 864" 1008" 1152" 1296" 1440" 1584" |
16' 20' 24' 28' 32' 36' 40' 44' |
Note: ShingleVent II and Multi-Pitch FilterVent provide 18" of net free area per linear foot.
INSTALLING A BALANCED RIDGE VENT SYSTEM
- Measure the square footage of the attic (length x width).
- Measure the length of the ridge.
- Refer to the chart above for required net free area and minimum length of ridge for attic square footage.
- Note: In most cases, the length of the ridge balanced with the same net free area of intake vents will satisfy FHA minimum standards and most building codes.
- Use the chart below to calculate the amount of intake vents that should be installed to balance your ridge vent system.
- Always install ridge vents from end to end across the entire ridge for best appearance and to provide maximum ventilation area.
- Hip roofs, dormers and T- or L-shaped roofs may require a specially designed ventilation system. For information, request a copy of Air Vent's Principles of Attic Ventilation.See Contact Us.
Balancing Your Ridge Vent System
Length of Ridge | Linear Feet of Continuous Soffit Vent |
Number of Undereave Vents | ||
16" x 8" | 16" x 6" | 16" x 4" | ||
15' | 30 | 5 | 6 | 10 |
20' | 40 | 6 | 9 | 13 |
30' | 60 | 10 | 13 | 19 |
40' | 80 | 13 | 17 | 26 |
50' | 100 | 16 | 21 | 32 |
60' | 120 | 19 | 26 | 39 |
70' | 140 | 23 | 30 | 45 |
80' | 160 | 26 | 34 | 51 |
90' | 180 | 29 | 39 | 58 |
Models
Models
ShingleVent II-9A
The same features as ShingleVent II, except that ShingleVent II-9A is 9" wide so that it can be used with cedar shakes or enhanced ridge cap shingles. Available in Charcoal.
Warranty
Learn about warranty coverage, transferability, limitations, other conditions and customer responsibilities. Read the full warranty and the list of eligible products. For Warranty information and questions, please contact us at: warranty@gibraltar1.com Download Full Air Vent Warranty Information Limited Warranty Proof of purchase is required when requesting warranty service. Limitations Air Vent reserves the right to discontinue or modify any of its products including color, and shall not be liable as a result of such discontinuation or modification, nor shall Air Vent be liable in the event replacement material may vary in color in comparison to the original product as a result of normal weathering. If Air Vent replaces any product under this warranty, it may substitute products designated by Air Vent to be of comparable quality or price range in the event the product initially installed has been discontinued or modified. Replacement Plus™ Protection In instances in which Air Vent, according to the terms of this warranty, has agreed to pay the cost of labor required to replace a defective intake vent, Air Vent will provide reimbursement only upon receipt of a copy of the contractor’s invoice or other written evidence of the completion of the work which Air Vent, at its sole discretion, deems acceptable. Transferability Motor Replacements Other Conditions The following warranty is effective 3/26/2021.
The Air Vent Product that you have purchased has a limited warranty from the date of purchase against defects in workmanship and materials. The length of the warranty varies by product. Please see attached chart for details. This warranty does not cover any labor costs, including those required for field repair or replacement or removal of any allegedly defective part.
The original purchaser must present a sales receipt or other document that establishes proof of purchase.
Please do not ship your fan or any fan parts to Air Vent unless requested to do so.
Air Vent shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with misuse, abuse, neglect or improper handling or staging , or installation not in strict adherence to Air Vent’s written instructions; impact of foreign objects, fire, flood, earthquake, lightning, hurricane, hail, tornado or other violent storms or other act of God; or defects in failure of or damage caused by materials used as roofing base over which the product is installed or by movement, distortion, cracking or settling of walls or the foundation of the building.
Products are covered by Replacement Plus™ protection (see attached for applicable products) for a period of time (varies by product) provided that the product has been installed in strict accordance with Air Vent’s written installation instructions. Under this warranty feature, Air Vent, at no charge, will replace any product found to be defective during the Replacement Plus™ period as long as proof of purchase is submitted to Air Vent (Replacement Plus™ period begins when the product installation is completed). Air Vent’s maximum liability under Replacement Plus will be equal to the reasonable cost to replace the defective product, including labor.
Provided that the products covered by this warranty have been installed in strict accordance with the Air Vent Inc. written installation instructions and in accordance with all local codes and standards, including those pertaining to fire-rated construction, Air Vent warrants to the original purchaser or first subsequent owner of the property that the product is free from manufacturing defects for the described length below from the date of purchase. If there is a change in ownership, the warranty may be transferred by the original purchaser of the product to the new owner (first subsequent owner) under the terms and conditions of this warranty.
The electrical motor is to be used solely as a direct replacement for a motor of the same model in an Air Vent, Inc, power attic ventilator. Using the motor in any other product could result in electrical shock and/or fire, which may cause property damage, serious injury or even death. Any motor replacement should be installed by a qualified licensed electrician in accordance with local, state and national electrical codes and standards. Make sure that power to the unit has been completely turned OFF at the breaker before approaching or inspecting the power attic ventilator or installing the replacement motor.
This warranty is expressly in lieu of all other oral or written warranties, liabilities or obligations of Air Vent. Pertinent state law shall control for what period of time subsequent to sale a consumer/homeowner may seek a remedy pursuant to the implied warranty of merchantability or fitness for a particular purpose. In no event shall Air Vent be liable for consequential or incidental damages of any kind, including any damage to the building, its contents or any persons therein, resulting from the breach of any warranty set forth herein, unless exclusion of these types of damages are specifically prohibited by state law. No field representative of Air Vent or any distributor or dealer is authorized to make any change or modifications to this warranty. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
Product
Model Number
Warranty
Replacement Plus Protection
ShingleVent ®II ridge vent (12", 9", Class A 9")
Limited Lifetime Warranty
5 year Replacement Plus™ protection
Peak Performer™ I & II Rolled ridge vent
Limited Lifetime Warranty
5 year Replacement Plus™ protection
The Edge™ Vent
Limited Lifetime Warranty
5 year Replacement Plus™ protection
Hip Ridge® Vent
Limited Lifetime Warranty
5 year Replacement Plus™ protection
VenturiVent™ Plus ridge vent and rolled ridge vent
Limited Lifetime Warranty
5 year Replacement Plus™ protection
ATTIC-AIRE™ ALL SEASONS™ Filtered Ridge Vent and Roll Vent
Limited Lifetime Warranty
5 year Replacement Plus™ protection
RidgeHawk™ Rolled ridge vent with nails
RH20
Limited Lifetime Warranty
ShadowHawk® Low Profile Vent
LPG72
Limited Lifetime Warranty
5 year Replacement Plus™ protection
Roof Mount Power Vent
ASRHP, SV3000, HE15WW
Limited Lifetime Warranty
5 year Replacement Plus™ protection
Roof Mount Power Vent
RV26, RV28, PC12
10 Year Limited Warranty
5 year Replacement Plus™ protection
Gable-Mount Power Vent
APG, APGH
Limited Lifetime Warranty
5 year Replacement Plus™ protection
Gable-Mount Power Fans (WCGB)- with Thermostat
Limited Lifetime Warranty
5 year Replacement Plus™ protection
Gable-Mount Power Fans (model WCGA)
5 Year Limited Warranty
5 year Replacement Plus™ protection
Roof Mount Solar Power Fans
NPSP8WW, SC8BL
5 Year Limited Warranty
2 year Replacement Plus™ protection
Gable Mount Solar Power Fans
NPSG8
5 Year Limited Warranty
2 year Replacement Plus™ protection
Whole-House Fans
10 Year Limited Warranty
5 year Replacement Plus™ protection
Roof Louvers/Static Vents
5 Year Limited Warranty
Airhawk® Wind Turbines
TIB, TOB series
Type B Gas Vent Cap
PTOP Series
5 Year Limited Warranty
Automatic Foundation Vent
5 Year Limited Warranty
Powered Foundation Vent
5 Year Limited Warranty
Low Voltage Foundation Vent
Series 5 & 6, Radon
5 Year Limited Warranty
Roof Mount Solar Power Fans
9010TR, 9025TR
5 Year Limited Warranty on Fan Motors
20 Year Limited on Solar Panel, Fan Housings
Gable Mount 20 Watt Solar Fan
1125APV
5 Year Limited Warranty on Fan Motors
20 Year Limited on Solar Panel, Fan Housings
Skylight Tubes
2214ST-LK
10 Year Limited Warranty
Archived Products
Product
Model Number
Warranty
Replacement Plus Protection
ShingleVent ®II ridge vent 7", Class A 7"
Limited Lifetime Warranty
5 year Replacement Plus™ protection
Ridge Vent 20’
MRV20
Limited Lifetime Warranty
Attic Aire™ Wind Turbines (WT series)
5 Year Limited Warranty
Roof Mount Solar Power Fans
9910TR, 9920TR, 9930TR
5 Year Limited Warranty on Fan Motors
20 Year Limited on Solar Panel, Fan Housings
Gable Mount 20 Watt Solar Fan
1020APV
5 Year Limited Warranty on Fan Motors
20 Year Limited on Solar Panel, Fan Housings
U.S. Sunlight Solar Controller
SC20
1 Year Limited Warranty on Unit, Remote
Skylight Tubes
1914ST, 2114ST
10 Year Limited Warranty